As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Polarion Vulnerabilities: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Restriction of XML External Entity Reference, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Observable Response Discrepancy 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow attackers to extract data, conduct cross-site scripting attacks or find out valid usernames. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Po...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: OZW Web Servers Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code on the device with root privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: OZW672: Versions prior to V8.0 (CVE-2025-26389) OZW672: Versions prior to V6.0 (CVE-2025-26390)...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM ROX II Vulnerabilities: Client-Side Enforcement of Server-Side Security 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM ROX MX5000: Versions prior to V2.16.5 RUGGEDCOM ROX RX1536: Versions prior to V2.16.5 RUGGEDCOM ROX RX5000: Versions prior to V2.1...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: MS/TP Point Pickup Module Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial of service condition that requires a power cycle to restore normal operation. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens MS/TP Point Pickup Module: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 The affected devices improperly handle specific incoming BACnet MSTP messages. This co...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 2.1 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: Mendix OIDC SSO Vulnerability: Incorrect Privilege Assignment 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to modify the system and gain administrator read/write privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens Mendix OIDC SSO (Mendix 9 compatible): All versions Siemens Mendix OIDC SSO (Mendix 10 compatible): All versions before V4.0.0 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT PRIVILEGE ASSIGNMENT CWE-266 The Mendix OIDC SSO module grants read and write access to all...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.3 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: APOGEE PXC and TALON TC Series Vulnerability: Expected Behavior Violation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a partial denial of service and reduce network availability. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens APOGEE PXC+TALON TC Series: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 EXPECTED BEHAVIOR VIOLATION CWE-440 The affected devices start sending unsolicited BACnet broadcast messages after processing a specific ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIRIUS 3RK3 Modular Safety System (MSS), SIRIUS Safety Relays 3SK2 Vulnerabilities: Use of a Broken or Risky Cryptographic Algorithm, Missing Encryption of Sensitive Data, Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to retrieve and de-obfuscate safety password, eavesdrop connections, or retrieve sensitive information from certain data records. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIRIUS 3RK3 ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Devices Vulnerabilities: Insufficiently Protected Credentials, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to retrieve LDAP credentials via modifying the LDAP server IP address in the FortiOS configuration to point to a malicious attacker-controlled server or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM APE1808: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 INSUFFICIENT...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: IPC RS-828A Vulnerability: Authentication Bypass by Spoofing 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following rugged industrial PCs are affected: SIMATIC IPC RS-828A: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 AUTHENTICATION BYPASS BY SPOOFING CWE-290 AMI's SPx contains a vulnerability in the BMC where an attacker ma...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 4.6 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: EcoStruxure Power Build Rapsody Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Schneider Electric EcoStruxure Power Build Rapsody is affected: EcoStruxure Power Build Rapsody: Version v2.7.12 FR and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 A CWE-121 Stack-based Buffer Overflow vulnerability exists that could cause local attackers being able to exploit these issues to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker. CVE-2025-3916 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). A CVSS v...