Siemens Solid Edge

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Solid Edge Vulnerabilities: Heap-based Buffer Overflow, Out-of-bounds Read, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: Solid Edge: All versions prior to V224.0 Update 5 (CVE-2024-33489, CVE-2024-33490, CVE-2024-33491, CVE-2024-33492, CVE-2024-33493) Solid Edge: All versions prior to V224.0 Update 2 (CVE-2024-34771, CVE-2024-34773) Solid Edge: All v...

us-cert
#vulnerability#web#buffer_overflow
Siemens Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Cerberus PRO UL and Desigo Fire Safety UL Vulnerabilities: Classic Buffer Overflow, Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected products (CVE-2024-22039) or create a denial-of-service condition (CVE-2024-22040, CVE-2024-22041). 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens,...

Siemens Parasolid

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Parasolid Vulnerabilities: Out-of-bounds Read, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process and crash the application causing a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Parasolid, a design and simulation product, are affected: Siemens Parasolid V35.1: Versions prior to V35.1.256 Siemens Parasolid V36.0: Versions prior to V36.0.208 Siemens Parasolid V36.1: Versions prior to V36.1.173 3.2 ...

Mitsubishi Electric Multiple FA Engineering Software Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Low attack complexity Vendor: Mitsubishi Electric Equipment: Multiple FA Engineering Software Products Vulnerabilities: Improper Privilege Management, Uncontrolled Resource Consumption, Out-of-bounds Write, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition and/or to gain Windows system privileges and execute arbitrary commands. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Mitsubishi Electric reports the following versions of FA Engineering Software Products are affected: CPU Module Logging Configuration Tool: All versions CSGL (GX Works2 connection configuration): All versions CW Configurator: All versions Data Transfer: All versions Data Transfer Classic: All versions EZSocket (communication middleware product for Mitsubishi Electric partner companies): All versions FR Configura...

SUBNET PowerSYSTEM Center and Substation Server

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerabilities: Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by PowerSYSTEM Center could allow privilege escalation, denial-of-service, or arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS SUBNET Solutions reports that the following products use components with vulnerabilities: PowerSYSTEM Center: Update 19 and prior 3.2 Vulnerability Overview 3.2.1 RELIANCE ON INSUFFICIENTLY TRUSTWORTHY COMPONENT CWE-1357 SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center. CVE-2024-28042 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2024-28042. A bas...

Johnson Controls Software House C-CURE 9000

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: low attack complexity Vendor: Johnson Controls Equipment: Software House C●CURE 9000 Vulnerability: Insertion of Sensitive Information into Log File 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to access credentials used for access to the application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Johnson Controls reports that the following versions of Software House C●CURE 9000, a security management system, are affected: Software House C●CURE 9000: v3.00.2 3.2 Vulnerability Overview 3.2.1 Insertion of Sensitive Information into Log File CWE-532 Under certain circumstances the Microsoft Internet Information Server (IIS) used to host the C●CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C●CURE 9000 or prior versions. CVE-2024-0912 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.7 has been calcul...

Rockwell Automation FactoryTalk Remote Access

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Factory Talk Remote Access Vulnerability: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to enter a malicious executable and run it as a system user, resulting in remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation's FactoryTalk Remote Access are affected: FactoryTalk Remote Access: v13.5.0.174 and prior 3.2 Vulnerability Overview 3.2.1 UNQUOTED SEARCH PATH OR ELEMENT CWE-428 An unquoted executable path exists in the affected products, possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a system user. A threat actor needs admin privileges to exploit this vulnerability. CVE-...

Rockwell Automation FactoryTalk Historian SE

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Historian SE Vulnerabilities: Missing Release of Resource after Effective Lifetime, Improper Check or Handling of Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation FactoryTalk Historian SE, a data management application, are affected: FactoryTalk Historian SE: Versions v9.0 and prior 3.2 Vulnerability Overview 3.2.1 MISSING RELEASE OF RESOURCE AFTER EFFECTIVE LIFETIME CWE-772 FactoryTalk Historian SE utilizes the AVEVA PI Server, which contains a vulnerability that could allow an unauthenticated user to cause a partial denial-of-service condition in the PI Message Subsystem of a PI Server by consuming available memory. This vulnerability exists in Fa...

alpitronic Hypercharger EV Charger

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: alpitronic Equipment: Hypercharger EV charger Vulnerability: Use of Default Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker disabling the device, bypassing payment, or accessing payment data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Hypercharger EV charger, a high power charging station, are affected: Hypercharger EV charger: all versions 3.2 Vulnerability Overview 3.2.1 USE OF DEFAULT CREDENTIALS CWE-1392 If misconfigured, the charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator. CVE-2024-4622 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H). A CVSS v4 sco...

Delta Electronics InfraSuite Device Master

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: InfraSuite Device Master Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Delta Electronics products are affected: InfraSuite Device Master: Versions 1.0.10 and prior 3.2 Vulnerability Overview 3.2.1 Deserialization of Untrusted Data CWE-502 Delta Electronics InfraSuite Device Master contains a deserialization of untrusted data vulnerability because it runs a version of Apache ActiveMQ (5.15.2) which is vulnerable to CVE-2023-46604. CVE-2023-46604 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2023-46604. A base score of 9.3 has been calculated...