Tag
#auth
LNER cyber attack exposes passenger contact details and journey data. No financial information or passwords were taken, but…
Several AI chatbot apps are leaking user data for several reasons, but mostly because security is an afterthought.
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M340, BMXNOE0100, and BMXNOE0110 Vulnerability: Files or Directories Accessible to External Parties 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to prevent firmware updates and disrupt the webserver's proper behavior by removing specific files or directories from the filesystem. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Modicon M340: All versions Modbus/TCP Ethernet Modicon M340 module: Versions prior to SV3.60 Modbus/TCP Ethernet Modicon M340 FactoryCast module: Versions prior to SV6.80 3.2 VULNERABILITY OVERVIEW 3.2.1 FILES OR DIRECTORIES ACCESSIBLE TO EXTERNAL PARTIES CWE-552 A Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 2.3 ATTENTION: Exploitable from adjacent network Vendor: Siemens Equipment: SINEC OS Vulnerabilities: Uncontrolled Resource Consumption, Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to access non-sensitive information without authentication or potentially cause a temporary denial of service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens RUGGEDCOM RST2428P (6GK6242-6PA00): All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED RESOURCE CONSUMPTION CWE-400 The affected d...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: User Management Component (UMC) Vulnerabilities: Stack-based Buffer Overflow, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC PCS neo V4.1: All versions Siemens SIMATIC PCS neo V5.0: All versions Siemens User Management Component (UMC): Versions prior to 2.15.1.3 3.2 VULNERABILITY OVERVIE...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Daikin Equipment: Security Gateway Vulnerability: Weak Password Recovery Mechanism for Forgotten Password 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Daikin Security Gateway are affected: Security Gateway: App: 100, Frm: 214 3.2 VULNERABILITY OVERVIEW 3.2.1 WEAK PASSWORD RECOVERY MECHANISM FOR FORGOTTEN PASSWORD CWE-640 Daikin Security Gateway is vulnerable to an authorization bypass through a user-controlled key vulnerability that could allow an attacker to bypass authentication. An unauthorized attacker could access the system without prior credentials. CVE-2025-10127 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 4.1 ATTENTION: Exploitable from an adjacent network Vendor: Schneider Electric Equipment: EcoStruxure Vulnerabilities: Uncontrolled Resource Consumption, Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclose sensitive credential data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Schneider Electric products are affected: EcoStruxure Building Operation Enterprise Server 7.x: Versions prior to 7.0.2.348 EcoStruxure Building Operation Enterprise Server 6.x: Versions prior to 6.0.4.10001 (CP8) EcoStruxure Building Operation Enterprise Server 5.x: Versions prior to 5.0.3.17009 (CP16) EcoStruxure Enterprise Server 7.x: Versions prior to 7.0.2.348 EcoStruxure Enterprise Server 6.x: Versions prior to 6.0.4.10001 (CP8) EcoStruxure Enterprise Server 5.x: Versions prior to 5.0.3.17009 (CP16) EcoStruxur...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Apogee PXC and Talon TC Devices Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to download the device's encrypted database file via BACnet. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: APOGEE PXC Series (BACnet): All versions APOGEE PXC Series (P2 Ethernet): All versions TALON TC Series (BACnet): All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUT...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIVaaS Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access or alter sensitive data without proper authorization. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIMATIC Virtualization as a Service (SIVaaS): All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732 The affected application exposes a network share without any authentication. ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable from a local network Vendor: Siemens Equipment: SINAMICS Drives Vulnerability: Improper Privilege Management 2. RISK EVALUATION Successful exploitation of this vulnerability could allow users to escalate their privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SINAMICS G220 V6.4: Versions prior to V6.4 HF2 Siemens SINAMICS S200 V6.4: All versions Siemens SINAMICS S210 V6.4: Versions prior to V6.4 HF2 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER PRIVILEGE MANAGEMENT CWE-269 The affected devices allow a factory reset to be executed without the requ...