Security
Headlines
HeadlinesLatestCVEs

Tag

#vulnerability

GHSA-vv39-3w5q-974q: Kubernetes allows Command Injection affecting Windows nodes via nodes/*/logs/query API

A security vulnerability has been discovered in Kubernetes windows nodes that could allow a user with the ability to query a node's '/logs' endpoint to execute arbitrary commands on the host. This CVE affects only Windows worker nodes. Your worker node is vulnerable to this issue if it is running one of the affected versions listed below.

ghsa
#vulnerability#web#windows#git#kubernetes
GHSA-hm54-fg2w-2g6j: MODX allows cross-site scripting (XSS) via an SVG file

A cross-site scripting (XSS) vulnerability has been identified in MODX prior to 3.1.0. The vulnerability allows authenticated users to upload SVG files containing malicious JavaScript code as profile images, which gets executed in victims' browsers when viewing the profile image.

Miniaudio and Adobe Acrobat Reader vulnerabilities

Cisco Talos’ Vulnerability Discovery & Research team recently disclosed a Miniaudio and three Adobe vulnerabilities.   The vulnerabilities mentioned in this blog post have been patched by their respective vendors, all in adherence to Cisco’s third-party vulnerability disclosure policy.     For Snort coverage

Patch it up: Old vulnerabilities are everyone’s problems

Thorsten picks apart some headlines, highlights Talos’ report on an unknown attacker predominantly targeting Japan, and asks, “Where is the victim, and does it matter?”

GHSA-h2rp-8vpx-q9r4: cheqd-node Security patch for upstream vulnerabilities in IBC-Go (ISA-2025-001) and Cosmos SDK (ISA-2025-002)

# Description There have been two upstream security advisories and associated patches published under [ISA-2025-001](https://github.com/cosmos/ibc-go/security/advisories/GHSA-4wf3-5qj9-368v) and [ISA-2025-002](https://github.com/cosmos/cosmos-sdk/security/advisories/GHSA-47ww-ff84-4jrg). **[ISA-2025-001](https://github.com/cosmos/ibc-go/security/advisories/GHSA-4wf3-5qj9-368v)** affects the IBC-Go package., where non-deterministic JSON unmarshalling of IBC Acknowledgements can result in a chain halt. **[ISA-2025-002](https://github.com/cosmos/cosmos-sdk/security/advisories/GHSA-47ww-ff84-4jrg)** affects the Cosmos SDK package, where `x/group` can halt when erroring in `EndBlocker`. ### Impact If unaddressed, this could result in a chain halt. ### Patches Validators, full nodes, and IBC relayers should upgrade to [cheqd-node v3.1.8](https://github.com/cheqd/cheqd-node/releases/tag/v3.1.8). This upgrade does not require a software upgrade proposal on-chain and is meant to be non st...

HealthTech Database Exposed 108GB Medical and Employment Records

A misconfigured database exposed 108.8 GB of sensitive data, including information on over 86,000 healthcare workers affiliated with…

GitHub Uncovers New ruby-saml Vulnerabilities Allowing Account Takeover Attacks

Two high-severity security flaws have been disclosed in the open-source ruby-saml library that could allow malicious actors to bypass Security Assertion Markup Language (SAML) authentication protections. SAML is an XML-based markup language and open-standard used for exchanging authentication and authorization data between parties, enabling features like single sign-on (SSO), which allows

Siemens SINEMA Remote Connect Server

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerabilities: Improper Output Neutralization for Logs, Missing Release of Resource after Effective Lifetime 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to send garbage to OpenVPN log, cause high CPU load, or extend the validity of a closing session. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: SINEMA Remote Connect Server: Versions prior to V3.2 SP3 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER OUTPUT NEUTRALIZATION FOR LOGS CWE-117 A ma...

Siemens Teamcenter Visualization and Tecnomatrix Plant Simulation

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Teamcenter Visualization and Tecnomatrix Plant Simulation Vulnerabilities: Out-of-bounds Write, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Read, Use After Free 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause the application to crash or potentially lead to arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Teamcenter Visualization V14.3: Versions prior to V14.3.0.13 Teamcenter Visualization V2312: Versions prior to V2312.0009 Teamcenter Vi...

Siemens Tecnomatix Plant Simulation

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Tecnomatix Plant Simulation Vulnerabilities: Files or Directories Accessible to External Parties 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthorized attacker to read or delete arbitrary files or the entire file system of the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Tecnomatix Plant Simulation V2302: All versions prior to V2302.0021 Siemens Tecnomatix Plant Simulation V2404: All versions prior to V2404.0010 3.2 VULNERABILITY OVERVIEW 3.2.1 FILES OR DIRECTORIES ACCES...