Siemens SIPROTEC and SICAM

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIPROTEC and SICAM Vulnerability: Improper Enforcement of Message Integrity During Transmission in a Communication Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could cause the network access server to grant the attacker access to the network with the attacker's desired authorization and without the need of knowing or guessing legitimate access credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products using the RADIUS protocol are affected: CPC80 Central Processing/Communication: All versions...

us-cert
#vulnerability#web#git#auth
Siemens Desigo

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Desigo Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Desigo CC: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 The affected server application fails to authenticate specific client requests. Modification of the client...

Siemens BACnet ATEC Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: BACnet ATEC Devices Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following BACnet ATEC products are affected: Siemens BACnet ATEC 550-440: All versions Siemens BACnet ATEC 550-441: All versions Siemens BACnet ATEC 550-445: All versions Siemens BACnet AT...

Siemens INTRALOG WMS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: INTRALOG WMS Vulnerabilities: Cleartext Transmission of Sensitive Information, Uncontrolled Resource Consumption, Use After Free, Improper Link Resolution Before File Access ('Link Following'), Improper Input Validation, Inefficient Algorithmic Complexity 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to bypass security features, cause a denial-of-service condition, or execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens INTRALOG WM...

Siemens RUGGEDCOM APE1808 Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Devices Vulnerabilities: Insufficiently Protected Credentials, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to retrieve LDAP credentials via modifying the LDAP server IP address in the FortiOS configuration to point to a malicious attacker-controlled server or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM APE1808: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 INSUFFICIENT...

Siemens VersiCharge AC Series EV Chargers

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: VersiCharge AC Series EV Chargers Vulnerabilities: Missing Immutable Root of Trust in Hardware, Initialization of a Resource with an Insecure Default 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0): All versions (CVE-2025-31929)...

Siemens IPC RS-828A

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: IPC RS-828A Vulnerability: Authentication Bypass by Spoofing 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following rugged industrial PCs are affected: SIMATIC IPC RS-828A: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 AUTHENTICATION BYPASS BY SPOOFING CWE-290 AMI's SPx contains a vulnerability in the BMC where an attacker ma...

Schneider Electric EcoStruxure Power Build Rapsody

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 4.6 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: EcoStruxure Power Build Rapsody Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Schneider Electric EcoStruxure Power Build Rapsody is affected: EcoStruxure Power Build Rapsody: Version v2.7.12 FR and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 A CWE-121 Stack-based Buffer Overflow vulnerability exists that could cause local attackers being able to exploit these issues to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker. CVE-2025-3916 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). A CVSS v...

Why Cloud Phone Systems are The Future of Business Communication

Over the years, many different technologies have transitioned to Cloud-based solutions, including ERP systems and email management platforms.…

Pen Testing for Compliance Only? It's Time to Change Your Approach

Imagine this: Your organization completed its annual penetration test in January, earning high marks for security compliance. In February, your development team deployed a routine software update. By April, attackers had already exploited a vulnerability introduced in that February update, gaining access to customer data weeks before being finally detected. This situation isn't theoretical: it