Source
us-cert
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Teamcenter Visualization and JT2Go Vulnerabilities: Stack-based Buffer Overflow, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to crash the application or perform arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Teamcenter Visualization and JT2Go are affected: JT2Go: All versions prior to V2406.0003 Teamcenter Visualization V14.2: All versions prior to V14.2.0.13 Teamcenter Visualization V14.3: All versions prior to V14.3.0.11 Teamcenter Visualization ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 CPUs Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0): Versions prior to V3.1.4 SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0): Versions prior to V3....
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Tecnomatix Plant Simulation Vulnerabilities: Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Write, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of this vulnerability could lead the application to crash or potentially lead to arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following versions of Tecnomatix Plant Simulation are affected: Tecnomatix Plant Simulation V2302: Versions prior to V2302.0016 Tecnomatix Plant Simulation V2404: Versions prior t...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: DataMosaix Private Cloud Vulnerabilities: Inadequate Encryption Strength, Out-of-bounds Write, Improper Check for Dropped Privileges, Reliance on Insufficiently Trustworthy Component, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a denial-of-service condition, view user data, or perform remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following versions of DataMosaix Private Cloud are affected: DataMosaix Private Cloud: Versions 7.07 and prior 3.2 Vulnerability Overview 3.2.1 Inadequate Encryption Strength CWE-326 DataMosaix Private Cloud utilizes GnuPG which contains a certificate signature vulnerability found in the SHA-1 algorithm. A threat actor could use this weakness to create forged certificate signatures. If exploited, a malicious us...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PowerFlex 6000T Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation PowerFlex 6000T are affected: PowerFlex 6000T: Versions 8.001, 8.002, 9.001 3.2 Vulnerability Overview 3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754 A denial-of-service vulnerability exists in the PowerFlex 600T. If the device is overloaded with requests, it will become unavailable. The device may require a power cycle to recover it if it does not re-establish a connection after it stops receiving requests. CVE-2024-9124 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string i...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Simcenter Nastran Vulnerabilities: Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following versions of Simcenter Nastran finite element method (FEM) solver are affected: Simcenter Nastran 2306: All versions Simcenter Nastran 2312: All versions Simcenter Nastran 2406: Versions prior to V2406.5000 3.2 Vulnerabili...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: DIAEnergie Vulnerabilities: SQL Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to retrieve records or cause a denial of service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Delta Electronics DIAEnergie, an industrial energy management system, are affected: DIAEnergie: Versions v1.10.01.008 and prior. 3.2 Vulnerability Overview 3.2.1 SQL Injection CWE-89 Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product. CVE-2024-43699 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculat...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: TEM Equipment: Opera Plus FM Family Transmitter Vulnerabilities: Missing Authentication for Critical Function, Cross-Site Request Forgery (CSRF) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of TEM Opera Plus FM Family Transmitter, a FM Transmitter, are affected: Opera Plus FM Family Transmitter: Version 35.45 3.2 Vulnerability Overview 3.2.1 Missing Authentication for Critical Function CWE-306 TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-on...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerabilities: Server-Side Request Forgery (SSRF), Inefficient Regular Expression Complexity, Cross-Site Request Forgery (CSRF) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an attacker bypassing a proxy, creating a denial-of-service condition, or viewing sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of PowerSYSTEM Center are affected: PowerSYSTEM Center: PSC 2020 v5.21.x and prior 3.2 Vulnerability Overview 3.2.1 SERVER-SIDE REQUEST FORGERY (SSRF) CWE-918 Vulnerable versions of PowerSYSTEM Center utilize Axios NPM package 0.21.0, which contains a Server-Side Request Forgery (SSRF) vulnerability where an attacker is able to bypass a proxy by providing a URL that responds with a redirect to a restricted host or IP address. CVE-2020-28168 has been assi...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Optigo Networks Equipment: ONS-S8 - Spectra Aggregation Switch Vulnerabilities: Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion'), Weak Authentication 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to achieve remote code execution, arbitrary file upload, or bypass authentication. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ONS-S8 - Spectra Aggregation Switch, an OT network management device, are affected: ONS-S8 - Spectra Aggregation Switch: 1.3.7 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER CONTROL OF FILENAME FOR INCLUDE/REQUIRE STATEMENT IN PHP PROGRAM ('PHP REMOTE FILE INCLUSION') CWE-98 The web service for ONS-S8 - Spectra Aggregation Switch includes functions which do not properly validate user input, allowing an attacker to traverse directories, b...