Tag
#buffer_overflow
A stack-based buffer overflow vulnerability exists in the confsrv confctl_set_app_language functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to stack-based buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.
A stack-based buffer overflow vulnerability exists in the confers ucloud_add_node_new functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to stack-based buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.
A stack-based buffer overflow vulnerability exists in the confsrv addTimeGroup functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to a buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.
A stack-based buffer overflow vulnerability was found inside ADM when using WebDAV due to the lack of data size validation. An attacker can exploit this vulnerability to run arbitrary code. Affected ADM versions include: 3.5.9.RUE3 and below, 4.0.5.RVI1 and below as well as 4.1.0.RJD1 and below.
Now-patched RCE bug impacts dozens of DrayTek Vigor router models
zlib through 1.2.12 has a heap-based buffer over-read or buffer overflow in inflate in inflate.c via a large gzip header extra field. NOTE: only applications that call inflateGetHeader are affected. Some common applications bundle the affected zlib source code but may be unable to call inflateGetHeader (e.g., see the nodejs/node reference).
**What is the version information for this release?** Microsoft Edge Version Date Released Based on Chromium Version 104.0.1293.47 8/5/2022 104.0.5112.79/80/81
The Uniwill SparkIO.sys driver 1.0 is vulnerable to a stack-based buffer overflow via IOCTL 0x40002008.
Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue.
Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have joined an RPL DODAG. After that, an attacker can send a DAO packet with a Target option that contains a prefix length larger than 128 bits. The problem was fixed after the release of Contiki-NG 4.7. Users unable to upgrade may apply the patch in Contiki-NG PR #1615.