Security
Headlines
HeadlinesLatestCVEs

Tag

#dos

Rockwell Automation 1756-ENT2R, 1756-EN4TR, 1756-EN4TRXT

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: 1756-ENT2R, 1756-EN4TR, 1756-EN4TRXT Vulnerabilities: Improper Input Validation, Improper Handling of Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an attacker causing a denial of service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Rockwell Automation products are affected: 1756-ENT2R: Versions prior to 7.001 1756-EN4TR: Versions prior to 7.001 1756-EN4TRXT: Versions prior to 7.001 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 A security issue exists in the protected mode of 1756-EN4TR and 1756-ENT2R communication modules, where a Concurrent Forward Close operation can trigger a Major Non-Recoverable (MNFR) fault. This condition may lead to unexpected system crashes and loss of device availability. CVE-2025-8007 has been assigned to this vulnerability. A CVSS v3 base sc...

us-cert
#vulnerability#web#dos
Siemens Third-Party Components in SINEC OS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Third-Party Components in SINEC OS Vulnerabilities: Improper Input Validation, Use After Free, Out-of-bounds Read, Incorrect Check of Function Return Value, Incorrect Comparison, Improper Control of Resource Identifiers ('Resource Injection'), Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), NULL Pointer Dereference, Excessive Platform Resource Consumption within a Loop, Allocation of Resources Without Limits or Throttling, Improper Restriction of Operations within the Bounds of a Memory Buffer, Buffer Copy with...

Siemens SINEC OS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3.1 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM, SCALANCE Vulnerabilities: NULL Pointer Dereference, Use After Free, Unchecked Input for Loop Condition, Out-of-bounds Write, Out-of-bounds Read, Uncontrolled Resource Consumption, Missing Encryption of Sensitive Data, Improper Restriction of Operations within the Bounds of a Memory Buffer, Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Deadlock, Improper Resource Locking, Improper Input Validation, Stack-based Buffer Overflow, Use of NullPointerException Catch to Detect NULL Pointer Dereference, I...

Rockwell Automation FLEX 5000 I/O

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Rockwell Automation Equipment: FLEX 5000 I/O Vulnerabilities: Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of FLEX 5000 I/O is affected: 5069-IF8: version V2.011 (CVE-2025-7861) 5069-IY8: version V2.011 (CVE-2025-7862) 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 A security issue exists due to improper handling of CIP Class 32's request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. CVE-2025-7861 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector s...

Siemens RUGGEDCOM CROSSBOW Station Access Controller

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM CROSSBOW Station Access Controller (SAC) Vulnerabilities: Heap-Based Buffer Overflow, Integer Overflow or Wraparound 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM CROSSBOW Station Access Controller (SAC): Versions prior to V5.7 3.2 VULNERABILITY OVERVIEW 3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122 An integer overflow can be trig...

Siemens SIPROTEC 4 and SIPROTEC 4 Compact

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC 4 Compact Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIPROTEC 4 6MD61: All versions SIPROTEC 4 7SJ62: All versions SIPROTEC 4 7SJ63: All versions SIPROTEC 4 7SJ64: All versions SIPROTEC 4 7SJ66: All versions SIPROTEC 4 7SS52: All versions SIPROTEC 4 7ST6: All...

Siemens SINEC Traffic Analyzer

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC Traffic Analyzer Vulnerabilities: NULL Pointer Dereference, Use After Free, Uncontrolled Resource Consumption, Execution with Unnecessary Privileges, Exposure of Sensitive Information to an Unauthorized Actor, Irrelevant Code, Channel Accessible by Non-Endpoint 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or gain elevated access and access to sensitive resources. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens...

Siemens BFCClient

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: BFCClient Vulnerabilities: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Out-of-bounds Read, Loop with Unreachable Exit Condition ('Infinite Loop'), Access of Resource Using Incompatible Type ('Type Confusion'), Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to read memory contents, to change the application behavior, or to create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are aff...

GHSA-xvr7-p2c6-j83w: swift-nio-http2 affected by HTTP/2 MadeYouReset vulnerability

The HTTP/2 [MadeYouReset vulnerability](https://galbarnahum.com/made-you-reset) has a mild effect on swift-nio-http2. swift-nio-http2 mostly protects against MadeYouReset by using a number of existing denial-of-service prevention patterns that we added in response to the RapidReset vulnerabilities. The result is that servers are not vulnerable to naive attacks based on MadeYouReset, and the naive PoC examples do not affect swift-nio-http2. However, in 1.38.0 we added some defense-in-depth measures as a precautionary measure that detect clients behaving "weirdly". These defense in depth measures tackle resource drain attacks where attackers interleave attack traffic with legitimate traffic to try to evade our existing DoS prevention mechanisms. We recommend all adopters move to 1.38.0 as soon as possible to mitigate against more sophisticated attacks that may appear in the future. We are very grateful to @galbarnahum, @AnatBB, and @YanivRL for their reporting and assistance with our...

GHSA-prj3-ccx8-p6x4: Netty affected by MadeYouReset HTTP/2 DDoS vulnerability

Below is a technical explanation of a newly discovered vulnerability in HTTP/2, which we refer to as “MadeYouReset.” ### MadeYouReset Vulnerability Summary The MadeYouReset DDoS vulnerability is a logical vulnerability in the HTTP/2 protocol, that uses malformed HTTP/2 control frames in order to break the max concurrent streams limit - which results in resource exhaustion and distributed denial of service. ### Mechanism The vulnerability uses malformed HTTP/2 control frames, or malformed flow, in order to make the server reset streams created by the client (using the RST_STREAM frame). The vulnerability could be triggered by several primitives, defined by the RFC of HTTP/2 (RFC 9113). The Primitives are: 1. WINDOW_UPDATE frame with an increment of 0 or an increment that makes the window exceed 2^31 - 1. (section 6.9 + 6.9.1) 2. HEADERS or DATA frames sent on a half-closed (remote) stream (which was closed using the END_STREAM flag). (note that for some implementations it's possible ...