Security
Headlines
HeadlinesLatestCVEs

Latest News

Seraphic Browser-Native Protection Now Available for Purchase on the CrowdStrike Marketplace

Las Vegas, United States, 16th September 2025, CyberNewsWire

HackRead
#web#intel#zero_day#sap#ssl
Siemens SIMATIC NET CP, SINEMA, and SCALANCE

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC NET CP, SINEMA and SCALANCE Vulnerabilities: Integer Overflow or Wraparound 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service (DoS) condition in the affected devices by exploiting integer overflow bugs. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2): < V7.1 Siemens SCALANCE M874-3 (6GK5874-3AA00-2AA2): < V7.1 Siemens SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2): < V7.1 ...

Siemens Multiple Industrial Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: INDUSTRIAL EDGE, OpenPCS, RUGGEDCOM, SCALANCE, SIMATIC, SIMOTION, SINAUT, SINEC, SIPLUS, TIA Vulnerability: Loop with Unreachable Exit Condition ('Infinite Loop') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Industrial Edge - OPC UA Connector: All versions prior to V1.7 Siemens RUGGEDCOM ROX MX5000RE: All versions prior to V2.15.1 Siemens SCALANCE W788-2 RJ45 (6GK5...

Siemens OpenSSL Vulnerability in Industrial Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: INDUSTRIAL EDGE, RUGGEDCOM, SCALANCE, SIMATIC, SINEC, SINEMA, SINUMERIK, SIPLUS, TIA Vulnerability: Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Industrial Edge - Machine Insight App: All versions Siemens RUGGEDCOM ROX RX1510: All versions prior to V2.15.0 Siemens SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6): All ...

Hitachi Energy RTU500 Series

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Vulnerabilities: NULL Pointer Dereference, Improper Validation of Integrity Check Value, Improper Restriction of XML External Entity Reference, Heap-based Buffer Overflow, Integer Overflow or Wraparound, Improper Restriction of Recursive Entity References in DTDs ('XML Entity Expansion'), Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a Denial-of-Service condition in RTU500 devices. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Hitachi Energy reports that the following products are affected: Hitachi Energy RTU500 series: Version 13.6.1 (CVE-2023-2953, CVE-2025-39203, CVE-2025-6021) Hitachi Energy RTU500 series: Versions 12.7.1 through 12.7.7 (CVE-2023-2953, CVE-2025-39203, CVE-2025-6021) Hitachi Energy RTU500 series: Versions 13.4.1 through 13.4.4 (CVE-2025-39203) Hitachi Energy RTU500 ...

Schneider Electric Altivar Products, ATVdPAC Module, ILC992 InterLink Converter

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Altivar products, ATVdPAC module, ILC992 InterLink Converter Vulnerability: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read or modify data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Schneider Electric ATVdPAC module: Versions prior to 25.0 Schneider Electric Altivar Process Drives ATV930: All versions Schneider Electric Altivar Process Drives ATV950: All versions Schneider Electric Altivar Process Drives ATV955: All versions Schneider Electric Altivar Process Drives ATV960: All versions Schneider Electric Altivar Process Drives ATV980: All versions Schneider Electric Altivar Process Drives ATV9A0: All versions Schneider Electric Altivar Process Drives A...

Innovative FileFix Phishing Attack Proves Plenty Potent

Highly deceptive FileFix uses code obfuscation and steganography and has been translated into at least 16 languages to power a global campaign.

Siemens RUGGEDCOM, SINEC NMS, and SINEMA

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM, SINEC NMS, and SINEMA Vulnerabilities: NULL Pointer Dereference, Out-of-bounds Write, Server-Side Request Forgery (SSRF) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service, crash the product, or perform remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens RUGGEDCOM NMS: All versions when using the device firmware upgrade mechanism (CVE-2021-34798) Siemens SINEC NMS: < V1.0.3 Siemens SINEMA Remote C...

Delta Electronics DIALink

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: DIALink Vulnerabilities: Path Traversal 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Delta Electronics DIALink are affected: DIALink: Versions V1.6.0.0 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22 Delta Electronics DIALink has an Improper Limitation of a Pathname to a Restricted Directory vulnerability which could allow an attacker to bypass authentication. CVE-2025-58320 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). A CVSS v4 score has also been calculated for CVE-2025-58320. A base score of 6.9 has been calculated; the C...

Ukrainian Fugitive Added to EU Most Wanted List for LockerGoga Ransomware

Ukrainian fugitive Volodymyr Tymoshchuk, linked to LockerGoga ransomware, has been added to the EU Most Wanted list as global authorities pursue him.