Siemens TIA Project-Server and TIA Portal

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Project-Server and TIA Portal Vulnerability: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: TIA Project-Server: Versions prior to V2.1.1 TIA Project-Server V17: All versions Totally Integrated Automation Portal (TIA Portal) V17: All versions Totally Integrated Automation Portal (TIA Portal) V18: All versions Totally Integrated A...

us-cert
#vulnerability#web#dos#perl
Siemens SIMATIC CN 4100

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CN 4100 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIMATIC CN 4100: All versions prior to V4.0 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial-of...

Siemens TIA Administrator

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Siemens Equipment: TIA Administrator Vulnerabilities: Improper Verification of Cryptographic Signature, Improper Access Control 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate privilege or execute arbitrary code during installations. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: TIA Administrator: All versions prior to V3.0.6 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347 The affected application improperly validates code signing certificates....

Siemens Solid Edge

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: High attack complexity Vendor: Siemens Equipment: Solid Edge SE2025 Vulnerabilities: Out-of-bounds Read, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to crash the application or execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Solid Edge SE2025: All versions prior to V225.0 Update 5 3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS READ CWE-125 The affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted PAR files. Thi...

Delta Electronics DTM Soft

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DTM Soft Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to encrypt files referencing the application in order to extract information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Delta Electronics products are affected: DTM Soft: Versions 1.6.0.0 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502 Delta DTM Soft is vulnerable to a deserialization of untrusted data vulnerability which may allow an attacker to extract information. CVE-2025-53415 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2025-53415. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR...

Siemens SIPROTEC 5

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.0 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SIPROTEC 5 Vulnerability: Use of GET Request Method With Sensitive Query Strings 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIPROTEC 5 6MD84 (CP300): All versions SIPROTEC 5 7SA86 (CP300): All versions SIPROTEC 5 7SA87 (CP300): All versions SIPROTEC 5 7SD82 (CP100): All versions SIPROTEC 5 7SD82 (CP150): A...

Advantech iView

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: iView Vulnerabilities: Cross-site Scripting, SQL Injection, Path Traversal, Argument Injection. 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, achieve remote code execution, or cause service disruptions. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Advantech products are affected: iView: Versions prior to 5.7.05 build 7057 3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-79 A vulnerability exists in Advantech iView versions prior to 5.7.05 build 7057, which could allow a reflected cross-site scripting (XSS) attack. By exploiting this flaw, an attacker could execute unauthorized scripts in the user's browser, potentially leading to information disclosure or other malicious activities. CVE-2025-53397 h...

End-of-Train and Head-of-Train Remote Linking Protocol

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.2 ATTENTION: Low attack complexity Standard: End-of-Train and Head-of-Train remote linking protocol Equipment: End-of-Train and Head-of-Train devices Vulnerability: Weak Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to send their own brake control commands to the end-of-train device, causing a sudden stoppage of the train which may lead to a disruption of operations, or induce brake failure. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of End-of-Train and Head-of-Train remote linking protocol is affected: End-of-Train and Head-of-Train remote linking protocol: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 WEAK AUTHENTICATION CWE-1390 The protocol used for remote linking over RF for End-of-Train and Head-of-Train (also known as a FRED) relies on a BCH checksum for packet creation. It is possible to create these EoT and HoT packets with a software defined radio and issue...

KUNBUS RevPi Webstatus

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: KUNBUS Equipment: RevPi Webstatus Vulnerability: Incorrect Implementation of Authentication Algorithm 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to bypass authentication and gain unauthorized access to the application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS KUNBUS reports the following products are affected: Revolution Pi Webstatus: Version 2.4.5 and prior Revolution Pi OS Bullseye: 04/2024 Revolution Pi OS Bullseye: 09/2023 Revolution Pi OS Bullseye: 07/2023 Revolution Pi OS Bullseye: 06/2023 Revolution Pi OS Bullseye: 02/2024 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT IMPLEMENTATION OF AUTHENTICATION ALGORITHM CWE-303 The Revolution Pi Webstatus application is vulnerable to an authentication bypass. The password check is vulnerable to an implicit type conversion. This results in incorrect authentication if the JSON value TRUE is prov...

Siemens SINEC NMS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Missing Authentication for Critical Function, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to elevate privileges and execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens SINEC NMS: All versions prior to V4.0 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROP...