View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: General Industrial Controls Equipment: Lynx+ Gateway Vulnerabilities: Weak Password Requirements, Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in obtaining sensitive device information, unauthorized access, or create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Lynx+ Gateway are affected: Lynx+ Gateway: Version R08 Lynx+ Gateway: Version V03 Lynx+ Gateway: Version V05 Lynx+ Gateway: Version V18 3.2 VULNERABILITY OVERVIEW 3.2.1 WEAK PASSWORD REQUIREMENTS CWE-521 The affected product is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login. CVE-2025-55034 has been assigned to this vulnerability. A C...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Software Center and Solid Edge Vulnerability: Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Software Center and Solid Edge are affected: Siemens Software Center: All versions prior to 3.5 Solid Edge SE2025: All versions prior to V225.0 Update 10 3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427 The affected application is vulnerabl...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Solid Edge Vulnerability: Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to perform man in the middle attacks. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Solid Edge SE2025: All versions prior to V225.0 Update 11 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER CERTIFICATE VALIDATION CWE-295 Affected applications do not properly validate client certificates to connect to License Service endpoint. This c...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: AADvance-Trusted SIS Workstation Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability may allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports the following versions of AADvance-Trusted SIS Workstation, a software suite for developing and managing safety instrumented system (SIS) applications, are affected: AADvance-Trusted SIS Workstation: Versions 2.00.00 to 2.00.04 3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CWE-22 A directory traversal vulnerability in DotNetZip v.1.16.0 and earlier may allow a remote attacker to execute arbitrary code via the src/Zip.Shared/ZipEntry.Extract.cs component. Exploitation requires the victim to open a malicious file. CVE-2024-48510 has been assigned to this vulnera...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC iQ-F Series Vulnerability: Improper Validation of Specified Quantity in Input 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Mitsubishi Electric MELSEC iQ-F Series are affected: FX5U-32MT/ES: All versions FX5U-32MT/DS: All versions FX5U-32MT/ESS: All versions FX5U-32MT/DSS: All versions FX5U-64MT/ES: All versions FX5U-64MT/DS: All versions FX5U-64MT/ESS: All versions FX5U-64MT/DSS: All versions FX5U-80MT/ES: All versions FX5U-80MT/DS: All versions FX5U-80MT/ESS: All versions FX5U-80MT/DSS: All versions FX5U-32MR/ES: All versions FX5U-32MR/DS: All versions FX5U-64MR/ES: All versions FX5U-64MR/DS: All versions FX5U-80MR/ES: All versions FX5U-80MR/DS: All versions FX5UC-32MT/D: All ver...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Verve Asset Manager Vulnerability: Incorrect Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker accessing or altering user data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Verve Asset Manager, an OT cybersecurity platform, are affected: Verve Asset Manager: Version 1.33 Verve Asset Manager: Version 1.34 Verve Asset Manager: Version 1.35 Verve Asset Manager: Version 1.36 Verve Asset Manager: Version 1.37 Verve Asset Manager: Version 1.38 Verve Asset Manager: Version 1.39 Verve Asset Manager: Version 1.40 Verve Asset Manager: Version 1.41 Verve Asset Manager: Version 1.41.1 Verve Asset Manager: Version 1.41.2 Verve Asset Manager: Version 1.41.3 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT AUTHORIZATION CWE-863 A security issue was discovered within Verve Asset Manager allowin...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk DataMosaix Private Cloud Vulnerabilities: Weak Authentication, Improper Encoding or Escaping of Output 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to take over accounts, steal credentials, redirect users to a malicious website, or bypass MFA. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of FactoryTalk DataMosaix Private Cloud are affected: FactoryTalk DataMosaix Private Cloud: Versions 7.11, 8.00, 8.01 (CVE-2025-11084) FactoryTalk DataMosaix Private Cloud: Versions 7.11, 8.00 (CVE-2025-11085) 3.2 VULNERABILITY OVERVIEW 3.2.1 WEAK AUTHENTICATION CWE-1390 A security issue exists within DataMosaix™ Private Cloud, allowing attackers to bypass MFA during setup and obtain a valid login-token cookie without knowing the users password. This vulnerability occurs when MFA is enabled...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM P850 family and SICAM P855 family Vulnerabilities: Cross-Site Request Forgery (CSRF), Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SICAM P850 (7KG8500-0AA00-0AA0): Versions prior to 3.11 SICAM P850 (7KG8501-0AA02-2AA0): Versions prior to 3.11 SICAM P85...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: COMOS Vulnerabilities: Incomplete List of Disallowed Inputs, Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or lead to data infiltration. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens COMOS with COMOS Web deployed: Versions prior to 10.4.5 (CVE-2023-45133) Siemens COMOS that use COMOS Snapshots component: Versions prior to 10.4.5 (CVE-2024-0056) 3.2 VULNERABILITY OVERVIEW 3.2....
The Race for Every New CVE Based on multiple 2025 industry reports: roughly 50 to 61 percent of newly disclosed vulnerabilities saw exploit code weaponized within 48 hours. Using the CISA Known Exploited Vulnerabilities Catalog as a reference, hundreds of software flaws are now confirmed as actively targeted within days of public disclosure. Each new announcement now triggers a global race