Source
us-cert
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: Pro-face GP-Pro EX and Remote HMI Vulnerability: Improper Enforcement of Message Integrity During Transmission in a Communication Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow man-in-the-middle attacks, resulting in information disclosure, integrity issues, and operational failures. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Pro-face GP-Pro EX and Remote HMI are affected: Pro-face GP-Pro EX: All versions Pro-face Remote HMI: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER ENFORCEMENT OF MESSAGE INTEGRITY DURING TRANSMISSION IN A COMMUNICATION CHANNEL CWE-924 The affected products are vulnerable to an improper enforcement of message integrity during transmission in a communication channel vulnerability that could cause partial loss of confidentiality, loss of integrity, and availability of the HMI when at...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC Vulnerability: Incorrect Calculation of Buffer Size 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service of the product when an unauthenticated user sends a crafted HTTPS packet to the webserver. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Modicon M580 PLCs, BMENOR2200H and EVLink Pro AC are affected: Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety): Versions prior to SV4.30 Modicon M580 CPU Safety (part numbers BMEP58-S and BMEH58-S): Versions prior to SV4.21 BMENOR2200H: All versions EVLink Pro AC: Versions prior to v1.3.10 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT CALCULATION OF BUFFER SIZE CWE-131 The affected product is vulnerable to an incorrect calculation of buffer size vulnerability which could cause a...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: Web Designer for Modicon Vulnerability: Improper Restriction of XML External Entity Reference 2. RISK EVALUATION Successful exploitation of this vulnerability could result in information disclosure, workstation integrity and potential remote code execution on the compromised computer. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Web Designer for Modicon are affected: Web Designer for BMXNOR0200H: All versions Web Designer for BMXNOE0110(H): All versions Web Designer for BMENOC0311(C): All versions Web Designer for BMENOC0321(C): All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611 The affected product is vulnerable to an improper restriction of XML external entity reference vulnerability that could cause information disclosure, impacts to workstation integrity, and potential remote code execution...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Elber Equipment: Communications Equipment Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Hidden Functionality 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker unauthorized administrative access to the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Elber Communications Equipment are affected: Signum DVB-S/S2 IRD: Versions 1.999 and prior Cleber/3 Broadcast Multi-Purpose Platform: Version 1.0 Reble610 M/ODU XPIC IP-ASI-SDH: Version 0.01 ESE DVB-S/S2 Satellite Receiver: Versions 1.5.179 and prior Wayber Analog/Digital Audio STL: Version 4 3.2 VULNERABILITY OVERVIEW 3.2.1 Authentication Bypass Using an Alternate Path or Channel CWE-288 Multiple Elber products are affected by an authentication bypass vulnerability which allows unauthorized access to ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M340 and BMXNOE0100/0110, BMXNOR0200H Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could cause information disclosure of a restricted web page, modification of a web page, and a denial of service when specific web pages are modified and restricted functions invoked. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Schneider Electric products, Modicon M340 and BMXNOE0100/0110, BMXNOR0200H, are affected: Modicon M340 processors (part numbers BMXP34*): All versions BMXNOE0100: All versions BMXNOE0110: All versions BMXNOR0200H: Versions prior to SV1.70IR26 3.2 VULNERABILITY OVERVIEW 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200 The affected products are vulnerable to an exposure of sensitive information to an unauthorized ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: AutomationDirect Equipment: C-more EA9 HMI Vulnerability: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition or achieve remote code execution on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Automation Direct products are affected: C-more EA9 HMI EA9-T6CL: v6.79 and prior C-more EA9 HMI EA9-T7CL-R: v6.79 and prior C-more EA9 HMI EA9-T7CL: v6.79 and prior C-more EA9 HMI EA9-T8CL: v6.79 and prior C-more EA9 HMI EA9-T10CL: v6.79 and prior C-more EA9 HMI EA9-T10WCL: v6.79 and prior C-more EA9 HMI EA9-T12CL: v6.79 and prior C-more EA9 HMI EA9-T15CL-R: v6.79 and prior C-more EA9 HMI EA9-T15CL: v6.79 and prior C-more EA9 HMI EA9-RHMI: v6.79 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 Buffer Copy without Checking S...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: 1756-L8zS3, 1756-L3zS3 Vulnerability: Improper Handling of Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote, non-privileged user to send malicious requests resulting in a major nonrecoverable fault causing a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Rockwell Automation products are affected: 1756-L8zS3: Versions prior to V33.017, V34.014, V35.013, V36.011 1756-L3zS3: Versions prior to V33.017, V34.014, V35.013, V36.011 3.2 VULNERABILITY OVERVIEW 3.2.1 Improper Handling of Exceptional Conditions CWE-755 A denial-of-service vulnerability exists in the affected products. The vulnerability could allow a remote, non-privileged user to send malicious requests resulting in a major nonrecoverable fault causing a denial-of-service. CVE-2025-24478 has been ass...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: UNEM Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Argument Injection, Heap-based Buffer Overflow, Improper Certificate Validation, Use of Hard-coded Password, Improper Restriction of Excessive Authentication Attempts, Cleartext Storage of Sensitive Information, Incorrect User Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial of service, execute unintended commands, access sensitive information, or execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Hitachi Energy reports that the following products are affected: UNEM: Versions R15A and prior UNEM: R15B (CVE-2024-28022, CVE-2024-28024, CVE-2024-28020) UNEM: R15B PC4 (CVE-2024-2013, CVE-2024-2012, CVE-2024-2011, CVE-2024-28021, CVE-2024-28023) UNEM: R16A UNEM: R16B (CVE-2024-28022, CVE-2024-280...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony Industrial PC, Pro-face Industrial PC Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: System Monitor application in Harmony Industrial PC: All versions System Monitor application in Pro-face Industrial PC: All versions 3.2 Vulnerability Overview 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200 An information exposure vulnerability exists that could cause exposure of credentials when attacker has access to application on network over HTTP. CVE-2024-8884 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (C...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk AssetCentre Vulnerabilities: Inadequate Encryption Strength, Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to extract passwords, access, credentials, or impersonate other users. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation FactoryTalk AssetCentre are affected: FactoryTalk AssetCentre: All versions prior to V15.00.001 3.2 Vulnerability Overview 3.2.1 INADEQUATE ENCRYPTION STRENGTH CWE-326 An encryption vulnerability exists in all versions prior to V15.00.001 of FactoryTalk AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application. CVE-2025-0477 has been assigned to this vulnerability. A CVSS v3.1 base scor...