Source
us-cert
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Data Center Expert Vulnerabilities: Improper Verification of Cryptographic Signature, Missing Authentication for Critical Function 2. RISK EVALUATION Exploitation of these vulnerabilities could allow an attacker to expose private data or achieve remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Schneider Electric Data Center Expert: 8.1.1.3 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347 An improper verification of cryptographic signature vulnerability exists that could compromise the Data Center Expert software when an upgrade bundle is manipulated to include arbitrary bash scripts that are executed as root. CVE-2024-8531 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 4.9 ATTENTION: Low attack complexity Vendor: Hitachi Energy Equipment: FOX61x, FOXCST, FOXMAN-UN Vulnerability: Improper Validation of Certificate with Host Mismatch 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to intercept or falsify data exchanges between the client and the server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Hitachi Energy reports that the following products are affected: FOX61x: Versions prior to R16B FOXCST: Versions prior to 16.2.1 FOXMAN-UN: R15A and prior FOXMAN-UN: R15B PC4 and prior FOXMAN-UN: R16A FOXMAN-UN: R16B PC2 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER VALIDATION OF CERTIFICATE WITH HOST MISMATCH CWE-297 Hitachi Energy is aware of a vulnerability that affects the FOXCST client application, which if exploited would allow attackers to intercept or falsify data exchanges between the client and the server. CVE-2024-2462 has been assigned to this vulnerability. A CVSS v...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.2 ATTENTION: Exploitable locally Vendor: Siemens Equipment: Siveillance Video Camera Drivers Vulnerability: Insertion of Sensitive Information into Log File 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to read camera credentials stored in the Recording Server under specific conditions. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siveillance Video Device Pack: Versions prior to V13.5 3.2 VULNERABILITY OVERVIEW 3.2.1 INSERTION OF SENSITIVE INFORMATION INTO LOG FILE CWE-532 Disclosure of sensitive information in HikVision camera driver...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: Mendix LDAP Vulnerability: LDAP Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to bypass username verification. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Mendix LDAP: All versions prior to 1.1.2 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN LDAP QUERY ('LDAP INJECTION') CWE-90 Affected versions of the module are vulnerable to LDAP injection. This could allow an unauthenticated remote attacker to ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 2.1 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: Industrial Edge Management Vulnerability: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to extract sensitive information by tricking users into accessing a malicious link. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Industrial Edge Management OS (IEM-OS): All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: EcoStruxure Power Monitoring Expert, EcoStruxure Power Operation, EcoStruxure Power SCADA Operation 2020 Vulnerability: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to tamper with folder names within the context of the product. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Schneider Electric EcoStruxure™ Power Monitoring Expert (PME) 2021: All versions prior to 2021 CU1 Schneider Electric EcoStruxure™ Power Monitoring Expert (PME) 2020: All versions prior to 2020 CU3 Schneider Electric EcoStruxure™ Power Operation (EPO) 2022: All versions prior to 2022 CU4 Schneider Electric EcoStruxure™ Power Operation (EPO) 2022 – Advanced Reporting and Dashboards Module: A...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: FOXMAN-UN Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Improper Neutralization of Argument Delimiters in a Command ('Argument Injection'), Heap-based Buffer Overflow, Incorrect User Management, Improper Certificate Validation, Improper Restriction of Excessive Authentication Attempts, Use of Hard-coded Password, Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated malicious user to interact with the services and the post-authentication attack surface. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Hitachi Energy reports that the following products are affected: Hitachi Energy FOXMAN-UN: All versions prior to R15A Hitachi Energy FOXMAN-UN: R15B (CVE-2024-28020, CVE-2024-28022, CVE-2024-28024) Hitachi Energy FOXMAN-UN: R15B PC4 (CVE-2024-2013, C...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Schneider Electric Equipment: Vijeo Designer Vulnerability: Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a non-admin authenticated user to perform privilege escalation by tampering with the binaries. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Schneider Electric Vijeo Designer: All versions prior to 6.3 SP1 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER PRIVILEGE MANAGEMENT CWE-269 Improper Privilege Management vulnerabilities exist that could cause unauthorized access, loss of confidentiality, integrity, and availability of the workstation if non-admin authenticated users try to perform privilege escalation by tampering with the binaries. CVE-2024-8306 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Belledonne Communications Equipment: Linphone-Desktop Vulnerability: NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of this vulnerability could could result in a remote attacker causing a denial-of-service condition on the affected devices. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of Linphone-Desktop is affected: Linphone-Desktop: Version 5.2.6 3.2 VULNERABILITY OVERVIEW 3.2.1 NULL POINTER DEREFERENCE CWE-476 The affected product is vulnerable to a NULL Dereference vulnerability, which could allow a remote attacker to create a denial-of-service condition. CVE-2025-0430 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A CVSS v4 score has also been calculated for CVE-2025-0430. A base score of 8.7 has been calculated; the CVSS vector st...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DRASimuCAD Vulnerabilities: Out-of-bounds Write, Type Confusion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device or potentially allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of DRASimuCAD, a robotic simulation platform, are affected: DRASimuCAD : Version 1.02.00.00 and prior 3.2 VUNERABILITY OVERVIEW 3.2.1 Access of Resource Using Incompatible Type ('Type Confusion') CWE-843 Delta Electronics DRASimuCAD expects a specific data type when it opens files, but the program will accept data of the wrong type from specially crafted files. CVE-2024-12834 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2024-12834. A base score of ...