The Dataprobe iBoot PDU running firmware version 1.43.03312023 or earlier uses hard-coded credentials for all interactions with the internal Postgres database.A malicious agent with the ability to execute operating system commands on the device can leverage this vulnerability to read, modify, or delete arbitrary database records.
Multiple security vulnerabilities impacting CyberPower's PowerPanel Enterprise Data Center Infrastructure Management (DCIM) platform and Dataprobe's iBoot Power Distribution Unit (PDU) could be potentially exploited to gain unauthenticated access to these systems and inflict catastrophic damage in target environments. The nine vulnerabilities, from CVE-2023-3259 through CVE-2023-3267, carry
Use of hard-coded credentials in some Intel(R) Unison(TM) software before version 10.12 may allow an authenticated user user to potentially enable information disclosure via local access.
In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges may use a command injection in a HTTP POST request releated to font configuration operations to gain full access to the device.
Given the privileged position these devices occupy on the networks they serve, they are prime targets for attackers, so their security posture is of paramount importance.
The threat actor known as Space Pirates has been linked to attacks against at least 16 organizations in Russia and Serbia over the past year by employing novel tactics and adding new cyber weapons to its arsenal. "The cybercriminals' main goals are still espionage and theft of confidential information, but the group has expanded its interests and the geography of its attacks," Positive
Fujitsu Real-time Video Transmission Gear "IP series" use hard-coded credentials, which may allow a remote unauthenticated attacker to initialize or reboot the products, and as a result, terminate the video transmission. Affected products and versions are as follows: IP-HE950E firmware versions V01L001 to V01L053, IP-HE950D firmware versions V01L001 to V01L053, IP-HE900E firmware versions V01L001 to V01L010, IP-HE900D firmware versions V01L001 to V01L004, IP-900E / IP-920E firmware versions V01L001 to V02L061, IP-900D / IP-900?D / IP-920D firmware versions V01L001 to V02L061, IP-90 firmware versions V01L001 to V01L013, and IP-9610 firmware versions V01L001 to V02L007.
Multiple security vulnerabilities have been discovered in various services, including Honeywell Experion distributed control system (DCS) and QuickBlox, that, if successfully exploited, could result in severe compromise of affected systems. Dubbed Crit.IX, the nine flaws in the Honeywell Experion DCS platform allow for "unauthorized remote code execution, which means an attacker would have
SmartBPM.NET has a vulnerability of using hard-coded authentication key. An unauthenticated remote attacker can exploit this vulnerability to access system with regular user privilege to read application data, and execute submission and approval processes.
SmartSoft SmartBPM.NET has a vulnerability of using hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code and disrupt service.