Security
Headlines
HeadlinesLatestCVEs

Tag

#js

Zero-Day Security Bug Likely Fueling Fortinet Firewall Attacks

An ongoing campaign targeting FortiGate devices with management interfaces exposed on the public Internet is leading to unauthorized administrative logins and configuration changes, creating new accounts, and performing SSL VPN authentication.

DARKReading
#vulnerability#web#cisco#js#git#auth#ssh#zero_day#ssl
ABB Cylon Aspect 3.08.02 (licenseServerUpdate.php) Stored Cross-Site Scripting

The ABB BMS/BAS controller suffers from an authenticated stored cross-site scripting vulnerability. Input passed to the 'host' POST parameter is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user's browser session in context of an affected site.

Schneider Electric Harmony HMI and Pro-face HMI Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony HMI and Pro-face HMI Products Vulnerability: Use of Unmaintained Third-Party Components 2. RISK EVALUATION Successful exploitation of this vulnerability could cause complete control of the device when an authenticated user installs malicious code into HMI product 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of Harmony HMI and Pro-face HMI are affected: Harmony HMIST6: All versions Harmony HMISTM6: All versions Harmony HMIG3U: All versions Harmony HMIG3X: All versions Harmony HMISTO7 series with Ecostruxure Operator Terminal Expert runtime: All versions PFXST6000: All versions PFXSTM6000: All versions PFXSP5000: All versions PFXGP4100 series with Pro-face BLUE runtime: All versions 3.2 Vulnerability Overview 3.2.1 USE OF UNMAINTAINED THIRD-PARTY COMPONENTS CWE-1104 The affected product is vulnerable...

Schneider Electric Harmony HMI and Pro-face HMI Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony HMI and Pro-face HMI Products Vulnerability: Use of Unmaintained Third-Party Components 2. RISK EVALUATION Successful exploitation of this vulnerability could cause complete control of the device when an authenticated user installs malicious code into HMI product 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of Harmony HMI and Pro-face HMI are affected: Harmony HMIST6: All versions Harmony HMISTM6: All versions Harmony HMIG3U: All versions Harmony HMIG3X: All versions Harmony HMISTO7 series with Ecostruxure Operator Terminal Expert runtime: All versions PFXST6000: All versions PFXSTM6000: All versions PFXSP5000: All versions PFXGP4100 series with Pro-face BLUE runtime: All versions 3.2 Vulnerability Overview 3.2.1 USE OF UNMAINTAINED THIRD-PARTY COMPONENTS CWE-1104 The affected product is vulnerable...

Schneider Electric PowerChute Serial Shutdown

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: PowerChute Serial Shutdown Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial of access to the web interface when someone on the local network repeatedly requests the /accessdenied URL. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of PowerChute Serial Shutdown are affected: PowerChute Serial Shutdown: Versions 1.2.0.301 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHENTICATION CWE-287 An improper authentication vulnerability exists that could cause a denial of access to the web interface when someone on the local network repeatedly requests the /accessdenied URL. CVE-2024-10511 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:...

Schneider Electric PowerChute Serial Shutdown

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: PowerChute Serial Shutdown Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial of access to the web interface when someone on the local network repeatedly requests the /accessdenied URL. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of PowerChute Serial Shutdown are affected: PowerChute Serial Shutdown: Versions 1.2.0.301 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHENTICATION CWE-287 An improper authentication vulnerability exists that could cause a denial of access to the web interface when someone on the local network repeatedly requests the /accessdenied URL. CVE-2024-10511 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:...

ABB Cylon Aspect 3.08.02 (webServerUpdate.php) Input Validation Config Poisoning

The ABB BMS/BAS controller suffers from improper input validation on the port POST parameter in the webServerUpdate.php script. This input is not validated on the server side and relies on bypassable client-side checks using the inString.js script to verify that the port parameter contains only characters from the set (0123456789). Attackers can bypass these checks and supply arbitrary integer values. Exploitation of this issue can result in configuration poisoning, Denial of Service (DoS) through malformed configurations, or manipulation of server settings via Cross-Site Request Forgery (CSRF) combined with authentication bypass.

India Readies Overhauled National Data Privacy Rules

The country awaits implementation guidelines for a framework that gives Indians greater autonomy and security over their personal data — and recognizes a right to personal privacy.

Green Bay Packers' Online Pro Shop Sacked by Payment Skimmer

Cyberattackers injected the NFL Wild Card team's online Pro Shop with malicious code to steal credit card data from 8,500 fans.

ABB Cylon Aspect 3.08.03 (MapServicesHandler) Authenticated Reflected XSS

The ABB BMS/BAS controller suffers from an authenticated reflected cross-site scripting vulnerability. Input passed to the GET parameters 'name' and 'id' is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user's browser session in context of an affected site.