Tag
#web
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Solid Edge Vulnerabilities: Heap-based Buffer Overflow, Out-of-bounds Read, Out-of-bounds Write, Stack-based Buffer Overflow, Access of Uninitialized Pointer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to use specially crafted PAR files to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products, are affected: Solid Edge SE2023: All versions prior to V223.0 Update 10 3.2 Vulnerability Overview 3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122 The affected application i...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.6 ATTENTION: Exploitable remotely, low attack complexity Vendor: Rapid Software LLC Equipment: Rapid SCADA Vulnerabilities: Path Traversal, Relative Path Traversal, Local Privilege Escalation through Incorrect Permission Assignment for Critical Resource, Open Redirect, Use of Hard-coded Credentials, Plaintext Storage of a Password, Generation of Error Message Containing Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an attacker reading sensitive files from the Rapid Scada server, writing files to the Rapid Scada directory (thus achieving code execution), gaining access to sensitive systems via legitimate-seeming phishing attacks, connecting to the server and perfoming attacks using the high privileges of a service, obtaining administrator passwords, learning sensitive information about the internal code of the application, or achieving remote code execution. 3. TECHNICAL DETAILS 3.1 AFFE...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Horner Automation Equipment: Cscape Vulnerability: Stack-Based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Horner Automation products are affected: Cscape: Versions 9.90 SP10 and prior 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 In Horner Automation Cscape versions 9.90 SP10 and prior, local attackers are able to exploit this vulnerability if a user opens a malicious CSP file, which would result in execution of arbitrary code on affected installations of Cscape. CVE-2023-7206 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing COUNTRIES/AREAS DEPLOYED: Worldwide COM...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3: 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Spectrum Power 7 Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated local attacker to inject arbitrary code and gain root access. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Spectrum Power 7: All versions prior to V23Q4 3.2 Vulnerability Overview 3.2.1 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732 The affected product's sudo configuration permits the local administrative account to execute several entries...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow and attacker to obtain remote unauthorized access. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products with maxView Storage Manager on Windows, are affected: SIMATIC IPC647E: All versions prior to V4.14.00.26068 SIMATIC IPC847E: All versions prior to V4.14.00.26068 SIMATIC IPC1047E: All versions prior to V4.14.00.26068 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 In default installations...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3: 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go, Teamcenter Visualization Vulnerabilities: Out-of-bounds Read, NULL Pointer Dereference, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the software's current process or crash the application causing a denial of service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: JT2Go: All versions prior to V14.3.0.6 Teamcenter Visualization V13.3: All versions prior to V13.3.0.13 Teamcenter Visualization V14.1: All versions prior to ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CN 4100 Vulnerabilities: Authorization Bypass Through User-Controlled Key, Improper Input Validation, Use of Default Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to remotely login as root or cause denial of service condition of the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SIMATIC CN 4100: Versions prior to V2.7 3.2 Vulnerability Overview 3.2.1 AUTHORIZATION BYPASS THROUGH USER-CONTROLLED KEY CWE-639 The "intermediate installation"...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: Easergy Studio Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain full control of a workstation. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Schneider Electric Easergy Studio, a power relay protection control software, are affected: Easergy Studio: Versions prior to v9.3.5 3.2 Vulnerability Overview 3.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502 A deserialization of untrusted data vulnerability exists in Schneider Electric Easergy Studio versions prior to v9.3.5 that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object. CVE-2023-7032 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/...
Cybersecurity researchers have identified an updated version of a macOS information stealer called Atomic (or AMOS), indicating that the threat actors behind the malware are actively enhancing its capabilities. "It looks like Atomic Stealer was updated around mid to late December 2023, where its developers introduced payload encryption in an effort to bypass detection rules,"
A pair of zero-day flaws identified in Ivanti Connect Secure (ICS) and Policy Secure have been chained by suspected China-linked nation-state actors to breach less than 10 customers. Cybersecurity firm Volexity, which identified the activity on the network of one of its customers in the second week of December 2023, attributed it to a hacking group it tracks under the name UTA0178