Latest News
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM CROSSBOW Station Access Controller (SAC) Vulnerabilities: Heap-Based Buffer Overflow, Integer Overflow or Wraparound 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM CROSSBOW Station Access Controller (SAC): Versions prior to V5.7 3.2 VULNERABILITY OVERVIEW 3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122 An integer overflow can be trig...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated administrator to execute unauthorized arbitrary OS commands. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM APE1808: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS C...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Simcenter Femap Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Simcenter Femap V2406: vers:intdot/<2406.0003 Siemens Simcenter Femap V2412: vers:intdot/<2412.0002 3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS WRITE CWE-787 The affected applications contain an out of bounds write vulnerability when parsing a specia...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Wibu CodeMeter Vulnerability: Least Privilege Violation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local user to navigate from Import License to a privileged instance of Windows Explorer. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC Information Server 2020: All versions Siemens SIMATIC WinCC OA V3.20: All versions prior to V3.20 P008 Siemens SIMATIC Information Server 2022: All versions Siemens SIMATIC Information Server 2024: All versions Siemens SIMATIC PDM Maintenanc...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: Opcenter Quality Vulnerabilities: Incorrect Authorization, Missing Encryption of Sensitive Data, Generation of Error Message Containing Sensitive Information, Insufficient Session Expiration, Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain complete access of the application, access to sensitive information, access to session information, or execute a Machine-In-The-Middle attack and compromise confidentiality and integrity of data. 3. TECHNI...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Third-Party Components in SINEC OS Vulnerabilities: Improper Input Validation, Use After Free, Out-of-bounds Read, Incorrect Check of Function Return Value, Incorrect Comparison, Improper Control of Resource Identifiers ('Resource Injection'), Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), NULL Pointer Dereference, Excessive Platform Resource Consumption within a Loop, Allocation of Resources Without Limits or Throttling, Improper Restriction of Operations within the Bounds of a Memory Buffer, Buffer Copy with...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: BFCClient Vulnerabilities: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Out-of-bounds Read, Loop with Unreachable Exit Condition ('Infinite Loop'), Access of Resource Using Incompatible Type ('Type Confusion'), Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to read memory contents, to change the application behavior, or to create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are aff...
You check that the windows are shut before leaving home. Return to the kitchen to verify that the oven and stove were definitely turned off. Maybe even circle back again to confirm the front door was properly closed. These automatic safety checks give you peace of mind because you know the unlikely but potentially dangerous consequences of forgetting – a break-in, fire, or worse. Your
Cybersecurity researchers have disclosed a new Android trojan called PhantomCard that abuses near-field communication (NFC) to conduct relay attacks for facilitating fraudulent transactions in attacks targeting banking customers in Brazil. "PhantomCard relays NFC data from a victim's banking card to the fraudster's device," ThreatFabric said in a report. "PhantomCard is based on
The breach of the US Courts records system came to light more than a month after the attack was discovered. Details about what was exposed—and who’s responsible—remain unclear.