GHSA-2vv2-3x8x-4gv7: Flowise OS command remote code execution

The Custom MCPs feature is designed to execute OS commands, for instance, using tools like `npx` to spin up local MCP Servers. However, Flowise's inherent authentication and authorization model is minimal and lacks role-based access controls (RBAC). Furthermore, in Flowise versions before 3.0.1 the default installation operates without authentication unless explicitly configured. This combination allows unauthenticated network attackers to execute unsandboxed OS commands.

ghsa
#vulnerability#rce#auth
GHSA-q4xx-mc3q-23x8: Flowise JS injection remote code execution

User-controlled input flows to an unsafe implementation of a dynamic Function constructor, allowing network attackers to run arbitrary unsandboxed JS code in the context of the host, by sending a simple POST request.

Siemens Engineering Platforms

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Engineering Platforms Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC PCS neo V4.1: All Versions Siemens SIMATIC WinCC V18: All Versions Siemens SIMATIC WinCC V19: All versions prior to V19 Update 4 Siemens SIMATIC WinCC V20: All Versions Siemens SIMO...

Siemens SIMATIC RTLS Locating Manager

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: SIMATIC RTLS Locating Manager Vulnerabilities: Reachable Assertion, Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial of service condition or escalate to higher access rights. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC RTLS Locating Manager: all versions prior to 3.3 3.2 VULNERABILITY OVERVIEW 3.2.1 REACHABLE ASSERTION CWE-617 Affected devices do not properly validate input sent to its listening port on the ...

Siemens Opcenter Quality

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).   View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: Opcenter Quality Vulnerabilities: Incorrect Authorization, Missing Encryption of Sensitive Data, Generation of Error Message Containing Sensitive Information, Insufficient Session Expiration, Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain complete access of the application, access to sensitive information, access to session information, or execute a Machine-In-The-Middle attack and compromise confidentiality and integrity of data. 3. TECHNI...

Siemens Third-Party Components in SINEC OS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Third-Party Components in SINEC OS Vulnerabilities: Improper Input Validation, Use After Free, Out-of-bounds Read, Incorrect Check of Function Return Value, Incorrect Comparison, Improper Control of Resource Identifiers ('Resource Injection'), Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), NULL Pointer Dereference, Excessive Platform Resource Consumption within a Loop, Allocation of Resources Without Limits or Throttling, Improper Restriction of Operations within the Bounds of a Memory Buffer, Buffer Copy with...

Siemens SIMATIC RTLS Locating Manager

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC RTLS Locating Manager Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated remote attacker to execute arbitrary code with high privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIMATIC RTLS Locating Manager: Versions prior to V3.2 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 Affected products do not properly validate input for a backup script. This could allow an authenticated remote ...

Siemens RUGGEDCOM ROX II

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM ROX II Family Vulnerability: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with a legitimate, highly privileged account on the web interface to upload arbitrary files onto the filesystem of the devices. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens RUGGEDCOM ROX MX5000: All versions Siemens RUGGEDCOM ROX RX1536: All versions Siemens RUGGEDCOM ROX RX5000: All versions Siemens RUGGEDCOM ROX MX5000RE: ...

Siemens SINEC OS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3.1 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM, SCALANCE Vulnerabilities: NULL Pointer Dereference, Use After Free, Unchecked Input for Loop Condition, Out-of-bounds Write, Out-of-bounds Read, Uncontrolled Resource Consumption, Missing Encryption of Sensitive Data, Improper Restriction of Operations within the Bounds of a Memory Buffer, Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Deadlock, Improper Resource Locking, Improper Input Validation, Stack-based Buffer Overflow, Use of NullPointerException Catch to Detect NULL Pointer Dereference, I...

Rockwell Automation ArmorBlock 5000 I/O - Webserver

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ArmorBlock 5000 I/O Vulnerabilities: Incorrect Authorization, Improper Authentication 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to predict session numbers or perform privileged actions. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ArmorBlock 5000 I/O are affected: 5032-CFGB16M12P5DR: Versions 1.011 and prior 5032-CFGB16M12DR: Versions 1.011 and prior 5032-CFGB16M12M12LDR: Versions 1.011 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 INCORRECT AUTHORIZATION CWE-863 A security issue exists within the 5032 16pt Digital Configurable module's webserver. The webserver's session number increments at an interval that correlates to the last two consecutive login session interval, making it predictable. CVE-2025-7773 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has be...