As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SICAM Q100, SICAM Q200 Vulnerabilities: Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated local attacker to extract the SMTP account password and use the configured SMTP service for arbitrary purposes. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens POWER METER SICAM Q100 (7KG9501-0AA01-0AA1): Versions 2.60 up to but not including 2.62 Siemens POWER METER SICAM Q100 (7KG9501-0AA01-2AA1): Versions 2.60 up to but not including 2.62 Si...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Action Manager Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local unauthenticated attacker to listen to communications and manipulate the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of FactoryTalk Action Manager, a software management platform, are affected: FactoryTalk Action Manager: Version 1.0.0 to 1.01 3.2 VULNERABILITY OVERVIEW 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200 A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcast over a WebSocket and can be intercepted by any local client listening on the connection. CVE-2025-7532 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calcul...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Third-Party Components in SINEC OS Vulnerabilities: Improper Input Validation, Use After Free, Out-of-bounds Read, Incorrect Check of Function Return Value, Incorrect Comparison, Improper Control of Resource Identifiers ('Resource Injection'), Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), NULL Pointer Dereference, Excessive Platform Resource Consumption within a Loop, Allocation of Resources Without Limits or Throttling, Improper Restriction of Operations within the Bounds of a Memory Buffer, Buffer Copy with...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: Opcenter Quality Vulnerabilities: Incorrect Authorization, Missing Encryption of Sensitive Data, Generation of Error Message Containing Sensitive Information, Insufficient Session Expiration, Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to gain complete access of the application, access to sensitive information, access to session information, or execute a Machine-In-The-Middle attack and compromise confidentiality and integrity of data. 3. TECHNI...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated administrator to execute unauthorized arbitrary OS commands. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM APE1808: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS C...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Engineering Platforms Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC PCS neo V4.1: All Versions Siemens SIMATIC WinCC V18: All Versions Siemens SIMATIC WinCC V19: All versions prior to V19 Update 4 Siemens SIMATIC WinCC V20: All Versions Siemens SIMO...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: SIMATIC RTLS Locating Manager Vulnerabilities: Reachable Assertion, Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial of service condition or escalate to higher access rights. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC RTLS Locating Manager: all versions prior to 3.3 3.2 VULNERABILITY OVERVIEW 3.2.1 REACHABLE ASSERTION CWE-617 Affected devices do not properly validate input sent to its listening port on the ...
## Summary The `steam-workshop-deploy` github action does not exclude the `.git` directory when packaging content for deployment and provides no built-in way to do so. If a `.git` folder exists in the target directory (e.g., due to a local Git repo, custom project structure, or via the `actions/checkout` workflow), it is silently included in the output package. This results in leakage of sensitive repository metadata and potentially credentials, including github personal access tokens (PATs) embedded in `.git/config`. Many game modding projects require packaging from the project root as the game expects certain files (assets, configuration, metadata) to be present at specific root-level paths. Consequently, the `.git` directory often exists alongside these required files and gets packaged unintentionally, especially when using `actions/checkout`. While github hosted runners automatically revoke ephemeral credentials at the end of each job, the severity of this issue increases dramat...
This vulnerability has been assigned the CVE identifier CVE-2025-55193 ### Impact The ID passed to `find` or similar methods may be logged without escaping. If this is directly to the terminal it may include unescaped ANSI sequences. ### Releases The fixed releases are available at the normal locations. ### Credits Thanks to [lio346](https://hackerone.com/lio346) for reporting this vulnerability
### Impact An attacker who uses this vulnerability can craft a PDF which leads to the RAM being exhausted. This requires just reading the file if a series of FlateDecode filters is used on a malicious cross-reference stream. Other content streams are affected on explicit access. ### Patches This has been fixed in [pypdf==6.0.0](https://github.com/py-pdf/pypdf/releases/tag/6.0.0). ### Workarounds If you cannot upgrade yet, you might want to implement the workaround for `pypdf.filters.decompress` yourself: https://github.com/py-pdf/pypdf/blob/0dd57738bbdcdb63f0fb43d8a6b3d222b6946595/pypdf/filters.py#L72-L143 ### References This issue has been reported in #3429 and fixed in #3430.