Tag
#auth
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: RUGGEDCOM ROX II family Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to bypass authentication and access a root shell on the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM ROX MX5000: All versions RUGGEDCOM ROX RX1536: All versions RUGGEDCOM ROX RX5000: All versions RUGGEDCOM ROX MX5000RE: All versions RUGGEDCOM ROX RX1400: All versions RUGGEDCOM ROX RX1500: All versions RUGGEDCOM ROX R...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SICAM Q100, SICAM Q200 Vulnerabilities: Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated local attacker to extract the SMTP account password and use the configured SMTP service for arbitrary purposes. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens POWER METER SICAM Q100 (7KG9501-0AA01-0AA1): Versions 2.60 up to but not including 2.62 Siemens POWER METER SICAM Q100 (7KG9501-0AA01-2AA1): Versions 2.60 up to but not including 2.62 Si...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Action Manager Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local unauthenticated attacker to listen to communications and manipulate the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of FactoryTalk Action Manager, a software management platform, are affected: FactoryTalk Action Manager: Version 1.0.0 to 1.01 3.2 VULNERABILITY OVERVIEW 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200 A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcast over a WebSocket and can be intercepted by any local client listening on the connection. CVE-2025-7532 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calcul...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated administrator to execute unauthorized arbitrary OS commands. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: RUGGEDCOM APE1808: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND ('OS C...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC 4 Compact Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIPROTEC 4 6MD61: All versions SIPROTEC 4 7SJ62: All versions SIPROTEC 4 7SJ63: All versions SIPROTEC 4 7SJ64: All versions SIPROTEC 4 7SJ66: All versions SIPROTEC 4 7SS52: All versions SIPROTEC 4 7ST6: All...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: SINUMERIK Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SINUMERIK 828D PPU.4: Versions prior to V4.95 SP5 SINUMERIK 828D PPU.5: Versions prior to V5.25 SP1 SINUMERIK 840D sl: Versions prior to V4.95 SP5 SINUMERIK MC: V...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC Traffic Analyzer Vulnerabilities: NULL Pointer Dereference, Use After Free, Uncontrolled Resource Consumption, Execution with Unnecessary Privileges, Exposure of Sensitive Information to an Unauthorized Actor, Irrelevant Code, Channel Accessible by Non-Endpoint 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or gain elevated access and access to sensitive resources. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Siemens...
## Summary The `steam-workshop-deploy` github action does not exclude the `.git` directory when packaging content for deployment and provides no built-in way to do so. If a `.git` folder exists in the target directory (e.g., due to a local Git repo, custom project structure, or via the `actions/checkout` workflow), it is silently included in the output package. This results in leakage of sensitive repository metadata and potentially credentials, including github personal access tokens (PATs) embedded in `.git/config`. Many game modding projects require packaging from the project root as the game expects certain files (assets, configuration, metadata) to be present at specific root-level paths. Consequently, the `.git` directory often exists alongside these required files and gets packaged unintentionally, especially when using `actions/checkout`. While github hosted runners automatically revoke ephemeral credentials at the end of each job, the severity of this issue increases dramat...
This vulnerability has been assigned the CVE identifier CVE-2025-55193 ### Impact The ID passed to `find` or similar methods may be logged without escaping. If this is directly to the terminal it may include unescaped ANSI sequences. ### Releases The fixed releases are available at the normal locations. ### Credits Thanks to [lio346](https://hackerone.com/lio346) for reporting this vulnerability
### Impact An attacker who uses this vulnerability can craft a PDF which leads to the RAM being exhausted. This requires just reading the file if a series of FlateDecode filters is used on a malicious cross-reference stream. Other content streams are affected on explicit access. ### Patches This has been fixed in [pypdf==6.0.0](https://github.com/py-pdf/pypdf/releases/tag/6.0.0). ### Workarounds If you cannot upgrade yet, you might want to implement the workaround for `pypdf.filters.decompress` yourself: https://github.com/py-pdf/pypdf/blob/0dd57738bbdcdb63f0fb43d8a6b3d222b6946595/pypdf/filters.py#L72-L143 ### References This issue has been reported in #3429 and fixed in #3430.